TAKO LIGHTNING PROTECTION SOLUTION – SOLE DISTRIBUTOR OF TELEBAHN SURGE PROTECTION DEVICE
Product Catalogue of Telebahn Surge Protection Devices
BS LC 24
产品概述
BS LC 24 可安装于 LPZ O₂ 及其紧界面,或直接安装于靠近绝缘电缆的端部。是 2 处非平坦且电源保护模块,适用于工业控制柜中传输系统的防护。本产品是根据 IEC 61643-21;GB/T 18802.21;YD/T 1542 标准设计。
Product Overview
BS LC 24 is installed at LPZ 0₂ or higher, or directly at the upstream near the protected devices. Provide protection for 2 single wires of unbalanced interfaces for measuring and controlling system. Designed according to IEC 61643-21; GB/T 18802.21; YD/T 1542.

技术参数 / Technical Specifications
5kA (total)
20kA (total)
≤ 45V (line-PE)
≤ 1ns (line-PE)
≤ 1.3nF (line-PE)
产品特点 / Product Features
模块化设计 / Modular design
由基座和电源保护模块两部分组成
Comprises two parts: the base and the protection module
安全保护 / Safe protection
更换模块时信号会自动断开
The signal will be disconnected when replacing the module
高性能 / High performance
放电能力强,电压保护级别低
High discharge capacity, low voltage protection level
应用范围 / Applications
BS LC 24 主要用于工业控制柜中,如现场总线,0-20mA,4~20mA 控制线等输入输出接口。
使用环境 / Application environment
- 工作温度:-40°C ~ +80°C
- 相对湿度:≤95% (25°C)
BS LC 24 is mainly used in lightning protection for measuring and controlling system, such as the field bus, input/output interface of the 0-20mA, 4-20mA control line.
Application environment
- Temperature: -40°C ~ +80°C
- Relative humidity: ≤95% (25°C)
安装说明 / Installation Instructions
安装步骤
- 本产品串联接入被保护设备
- 安装在35mm电气安装导轨上
- 产品IN(1,2)端为输入端,与信号通道相连;OUT(3,4)端为输出端
- 产品两侧各有一个接地端子,建议使用输出侧接地端子,接地线必须连接至接地系统,建议使用2.5mm²电缆,接地线应尽可能短
- 安装完成后应检查电路是否正常工作
Installation steps
- This product is connected in series to the protected device
- Mount on the 35mm DIN rail
- The IN terminal should be connected to the signal channel; OUT terminal to the protected devices
- There is a grounding terminal in each side, recommended to use the one at output side, earth lead must be connected to the earthing system, ideally using 2.5mm² cable. The cable should be as short as possible
- After installation, ensure the circuit is functioning

特别警示 / WARNING:
1. 安装人员须具有防雷专业资质并且按照施工安全等级要求操作和安装。
2. 为了您的安全,我们强烈建议在断开设备电源的情况下安装,以免发生意外。
1. The device must be installed by electrically skilled person, conforming to national standards and safety regulations.
2. It is recommended that installation should be done under power off condition.
维护说明 / Maintenance
安装完成后应定期检查电涌保护器的工作情况,特别是雷电过后,应及时检查。一旦发现通信受损,应及时更换。
Regularly inspect the operating status, especially after lightning. Once the communication is off, electrician should check/replace the SPD.
BS RJ45G 48
产品概述
BS RJ45G 48 适用于安装在 LPZ 0/2 及更高界面或直接安装在设备附近;符合 IEC 标准的 CAT 6 或 E 类综合布线系统;适用于所有工业以太网 10M、100M、1GB/t 网络电涌保护。兼容 IEEE 802.3at 标准。
Product Overview
BS RJ45G 48 is for installation at LPZ 0/2 and higher interface or directly installed near the equipment; according to IEC standard for CAT 6 or Class E integrated wiring system; provides surge protection for all industrial Ethernet 10M, 100M, 1GB/t networks. Compliant with IEEE 802.3at.

技术参数 / Technical Specifications
2.8kA (line-PE)
≤ 600V (line-PE)
≤ 25pF (line-PE)
产品特点 / Product Features
全面保护 / Comprehensive protection
用于保护计算机数据传输系统、网络系统等
For protecting computer data transmission system, network system
高性能 / High performance
放电能力强,电压保护级别低
Good discharge capacity, low voltage protection level
高速传输 / High-speed transmission
响应迅速,传输速度快,信号衰减低
Quick response, high transmission speed, low signal attenuation
便捷安装 / Easy installation
RJ45连接器,安装方便
RJ45 connector, easy for installation
应用范围 / Applications
BS RJ45G 48 应用于办公室和工业环境,如千兆以太网、ATM 或 ISDN 系统,以及 VoIP 或 PoE 系统等需要保护的设备(例如交换机、路由器、集线器、调制解调器等)。
使用环境 / Application environment
- 工作温度:-40°C ~ +80°C
- 相对湿度:≤95% (25°C)
BS RJ45G 48 is applied in offices and industries like Gigabit Ethernet, ATM or ISDN system, and like VoIP or PoE system can be protected (e.g. Switch, router, HUB, modem and so on).
Application environment
- Temperature: -40°C ~ +80°C
- Relative humidity: ≤95% (25°C)
安装说明 / Installation Instructions
安装步骤
- 本产品串联接入被保护设备
- 安装在35mm DIN导轨上
- OUT端子应连接至被保护设备
- SPD的接地端子必须连接至被保护设备金属外壳附近的接地汇流排
- 完成上述步骤后,应确保电路正常工作
多产品安装
多个产品安装时,可使用E-3、E-5或E-10母线将所有接地端子连接至地。
重要提示:输入电缆和输出电缆必须分开铺设,否则会造成干扰!
Installation steps
- This product is connected in series of the protected device
- Mount SPD on 35mm DIN rail
- The OUT terminal should be connected to the protected devices
- SPD’s earthing terminal must be connected to nearby earthing busbar of the metal earthing enclosure of the protected device
- After above, you should ensure the circuit is functioning
Multiple products installation
For multiple products installation, busbar E-3, E-5 or E-10 can be used to combine all the earth terminals to earth.
Important: Input cable and output cable must be laid out separately, otherwise it will cause interference!

推荐配件 / Recommended accessories:
- E-5 (No. 650 0007)
- E-4 (No. 550 0009)
- E-10 (No. 559 0005)
特别警示 / WARNING:
1. 必须由具备电气专业技能的人员安装,符合国家标准和安全规范。
2. 建议在断电状态下进行安装。
1. The device must be installed by electrically skilled person, conforming to national standards and safety regulations.
2. It is recommended that installation should be done under power off condition.
维护说明 / Maintenance
应定期检查工作状态,特别是雷雨过后。一旦通信中断,电工应检查/更换SPD。
Regularly inspect the operating status, especially after lightning. Once the communication is off, electrician should check/replace the SPD.
BS NP 4TP 1X G48
产品概述
BS NP 4TP 1X G48安装于 LPZ0-2 或更高界面,可以安装在 19″ 机柜里。根据 IEC 标准 CAT 6 或 E 类综合布线系统设计,适用于 10M、100M、1GB 网络防雷保护。兼容 IEEE 802.3at 标准。
Product Overview
BS NP 4TP 1X G48 can be installed at LPZ0-2 interface or higher, it can be installed in 19″ distribution cabinet, designed according to IEC standard CAT 6 or Class E integrated wiring system, it applies to all the industrial Ethernet 10M, 100M, 1GB network surge protection. Applicable to IEEE 802.3at.

技术参数 / Technical Specifications
10kA (total)
≤ 600V (line-PE)
≤ 25pF (line-PE)
产品特点 / Product Features
机架式设计 / Rack-mounted design
标准19英寸机架安装,节省空间
Standard 19″ rack mounting, space-saving
高性能保护 / High-performance protection
电压保护级别低,响应速度快
Low voltage protection level, quick response
低信号损耗 / Low signal loss
插入损耗低,保证信号质量
Low insertion loss, ensures signal quality
多端口设计 / Multi-port design
8个RJ45端口,满足多设备连接需求
8 RJ45 ports for multiple device connections
应用范围 / Applications
BS NP 4TP 1X G48 适用于办公室和工业环境,如千兆以太网、ATM 或 ISDN 系统,以及 VoIP 或 PoE 系统(例如交换机、路由器、集线器、调制解调器等)。
使用环境 / Application environment
- 工作温度:-40°C ~ +80°C
- 相对湿度:≤95% (25°C)
BS NP 4TP 1X G48 is applied in offices and industries like Gigabit Ethernet, ATM or ISDN system, and VoIP or PoE system (e.g. Switch, router, HUB, modem and so on).
Application environment
- Temperature: -40°C ~ +80°C
- Relative humidity: ≤95% (25°C)
安装说明 / Installation Instructions
安装步骤
- 本产品串联接入被保护设备
- 可安装在标准19″配电机架上
- OUT端子应连接至被保护设备
- SPD的接地端子必须连接至被保护设备金属外壳附近的接地汇流排
- 完成上述步骤后,应确保电路正常工作
Installation steps
- This product is connected in series to the protected device
- Can be mounted in standard 19″ distribution cabinet
- The OUT terminal should be connected to the protected devices
- SPD’s earthing terminal must be connected to nearby earthing BusBar or the metal earthing enclosure of protected device
- After above, you should ensure the circuit is functioning

特别警示 / WARNING:
1. 必须由具备电气专业技能的人员安装,符合国家标准和安全规范。
2. 建议在断电状态下进行安装。
1. The device must be installed by electrically skilled person, conforming to national standards and safety regulations.
2. It is recommended that installation should be done under power off condition.
维护说明 / Maintenance
应定期检查工作状态,特别是雷雨过后。一旦通信中断,电工应检查/更换SPD。
Regularly inspect the operating status, especially after lightning. Once the communication is off, electrician should check/replace the SPD.
BT P BCM 25 RM/3+N
产品概述
BT P BCM 25 RM/3+N 适用于安装在 LPZ1 或更高区域,保护低压设备免受雷击和电涌损坏。专为 TNTT 系统(“3+N 电路”)设计,适用于 SPD-Class I (B级) 或各种电源系统的雷电电流电涌保护。根据 IEC 61643-11、EN 61643-11、GB/T 18802.11 标准设计。
Product Overview
BT P BCM 25 RM/3+N is for installation at LPZ1 or higher, protecting low-voltage equipment against lightning and surge damages. Specially designed for TNTT systems (“3+N circuit”). Applied to SPD-Class I (Class B) or various power supply systems of lightning current surge protection. Designed according to IEC 61643-11, EN 61643-11, GB/T 18802.11.

技术参数 / Technical Specifications
≤ 2.5kV (L-PE)
10mm²-35mm² solid / 50mm² flexible
产品特点 / Product Features
三相保护 / Three-phase protection
专为TNTT系统(“3+N电路”)设计的三相保护
Three-phase protection specially designed for TNTT systems (“3+N circuit”)
先进技术 / Advanced technology
采用辅助触发GDT技术,高续流遮断能力
Assisted triggered GDT technology, high follow current extinguishing capability
双重保护 / Dual protection
双热脱扣装置,提供更可靠的保护
Double thermal disconnection devices, provide more reliable protection
状态指示 / Status indication
故障时绿色窗口会变色,同时提供远程报警端子
Green window changes when fault occurs, with remote alarm terminal
应用范围 / Applications
BT P BCM 25 RM/3+N 主要用于安装在室内主配电箱中,用于泄放直击雷电流。
典型安装位置 / Typical installation locations
- 楼层配电箱
- I级主配电箱
- LPZ1或更高区域的配电系统
BT P BCM 25 RM/3+N is mainly for installing in indoor main power distribution-box to discharge direct lightning current.
Typical installation locations
- Floor distributor-box
- Class I main distributor-box
- Power distribution systems at LPZ1 or higher
安装说明 / Installation Instructions
安装步骤
- 检查产品包装完整性,确保产品无损坏部件
- 将产品安装在35mm DIN导轨上
- 连接导线,导线截面积必须大于10mm²。导线耐压值不小于AC50V,确保接线可靠
- 如需远程报警,应连接至2和3端子(正常时2和3断开,故障时2和3闭合)
- 安装完成后,接通电源并合上电路断路器。如果SPD窗口未显示红色,表示工作正常
后备保护要求
后备保护熔断器必须安装在SPD的上游,确保被保护系统具有双重保护。SPD系统中使用的熔断器值应满足:
- 熔断器的值不应大于SPD后备保护熔断器的最大耐受能力
- 在电源最大电流和闭合回路可用电流状态下,熔断器应能断开过载或短路电流
- 在1.5级配置中,熔断器应尽可能大以允许SPD的最大浪涌放电
Installation steps
- Check the product for integrity of the package; make sure the product involves undamaged parts
- Mount on 35mm DIN rail
- Connect conductors, the cross-sectional area must be larger than 10mm². The withstand voltage value is not smaller than AC50V; ensure wiring reliable
- If remote alarm needed, connect to terminal 2 and 3 (normally open, closes when fault occurs)
- After installation, switch on the power supply and turn on the circuit breaker. If the SPD’s window does not appear red, it is operating normally
Backup protection requirements
Fuse must be installed at the upstream of the SPD to ensure double protection. The value of the fuse used in a SPD system should confirm to:
- The value of fuse should not be larger than the max. withstand capacity of the SPD’s backup fuse value
- Under the status of the max. current in the power supply & close loop circuit available current, the fuse should be able to discontinue current if overloaded or short-circuited
- In 1.5 class configuration, the fuse should be as large as possible to allow the maximum surge discharge of SPD

特别警示 / WARNING:
1. 必须由具备电气专业技能的人员安装,符合国家标准和安全规范。
2. 建议在断电状态下进行安装。
1. The device must be installed by electrically skilled person, conforming to national standards and safety regulations.
2. It is recommended that installation should be done under power off condition.
维护说明 / Maintenance
应定期检查工作状态,特别是雷雨过后。一旦上游熔断器断开或SPD窗口显示红色,电工应检查/更换SPD。
Regularly inspect the operating status, especially after lightning. Once the fuse upstream breaks, or the SPD’s window indicates red, electrician should check/replace the SPD.
BT PCM80 275 RM/2P
产品概述
BT PCM80 275 RM/2P 适用于安装在 LPZ2 或更高区域,保护低压设备免受电涌损坏。专为 TN 系统(“2-0″电路)设计,适用于 SPD Class II (C级) 各种电源系统的雷电电流电涌保护。根据 IEC 61643-11、EN 61643-11、GB/T 18802.11 标准设计。
Product Overview
BT PCM80 275 RM/2P is for installation at LPZ2 or higher, protect low voltage devices from surge damages. Specially designed for TN system (“2-0” circuit), applied to SPD Class II (Class C) for various power supply systems of lightning current surge protection. Designed according to IEC 61643-11; EN 61643-11; GB/T 18802-11.

技术参数 / Technical Specifications
1.5mm²-25mm² solid / 35mm² flexible
DC:250V/0.1A;125V/0.2A;75V/0.5A
产品特点 / Product Features
单相保护 / Single-phase protection
专为TN系统(“2-0″电路)设计的单相保护
Single-phase protection specially designed for TN system (“2-0” circuit)
高性能 / High performance
高放电能力,快速响应,可插拔设计
High discharge capacity, quick response, pluggable
双重保护 / Dual protection
双热脱扣装置,提供更可靠的保护
Double thermal disconnection devices, providing more reliable protection
状态指示 / Status indication
故障时窗口变色,同时提供远程报警控制
Window changes color when fault occurs, with remote alarm control
应用范围 / Applications
BT PCM80 275 RM/2P 应用于 II 类单相 TN 系统。主要用于配电室、配电柜和其他重要电源系统等供电系统。
典型安装位置 / Typical installation locations
- 配电箱
- UPS馈线总线
- LPZ2或更高区域的配电系统
使用环境 / Application environment
- 工作温度:-40°C ~ +80°C
- 相对湿度:≤95% (25°C)
BT PCM80 275 RM/2P is applied in class II single-phase TN system. Mainly used in power supply system such as power distribution-room, distribution-cabinet and other important power supply systems.
Typical installation locations
- Distribution box
- Feeder bus of UPS
- Power distribution systems at LPZ2 or higher
Application environment
- Temperature: -40°C ~ +80°C
- Relative humidity: ≤95% (25°C)
安装说明 / Installation Instructions
安装步骤
- 检查产品包装完整性,确保产品无损坏部件
- 将产品安装在35mm DIN导轨上
- 连接导线,导线截面积必须大于4mm²。导线耐压值不小于AC50V/0.5MHz,确保接线可靠
- 如需远程报警,应连接至1和3或2和3端子(正常时2和3断开,1和3闭合;故障时状态相反)
- 安装完成后,接通电源并合上电路断路器。SPD窗口显示绿色表示工作正常
后备保护要求
后备保护熔断器必须安装在SPD的上游,确保被保护系统具有双重保护。SPD系统中使用的熔断器值应满足:
- 熔断器的值不应大于SPD后备保护熔断器的最大耐受能力
- 在电源最大电流和闭合回路可用电流状态下,熔断器应能断开过载或短路电流
- 在1.2级配置中,熔断器应尽可能大以允许SPD的最大浪涌放电
Installation steps
- Check the product for integrity of the package; make sure the product is undamaged
- Mount the SPD on the 35mm DIN rail
- Connect conductors, the cross-sectional area must be larger than 4mm². The withstand voltage value is not smaller than AC50V/0.5MHz, ensure wiring reliable
- If remote alarm needed, connect to terminal 1 and 3, or 2 and 3 (normally 2 and 3 open, 1 and 3 close; when fault, the state is reversed)
- After installation, switch on the power supply and turn on the circuit breaker. The SPD’s window indicates green when operating normally
Backup protection requirements
Fuse must be installed at the upstream of the SPD to ensure double protection. The value of the fuse used in a SPD system should confirm to:
- The value of fuse should not be larger than the max. withstand capacity of the SPD’s backup fuse value
- Under the status of the max. current in the power supply & close loop circuit available current, the fuse should be able to disconnect when overloaded or short-circuited
- In 1.2 class configuration, the fuse should be as large as possible to allow the maximum surge discharge of SPD

特别警示 / WARNING:
1. 必须由具备电气专业技能的人员安装,符合国家标准和安全规范。
2. 建议在断电状态下进行安装。
1. The device must be installed by electrically skilled person, conforming to national standards and safety regulations.
2. It is recommended that installation should be done under power off condition.
维护说明 / Maintenance
应定期检查工作状态,特别是雷雨过后。一旦上游熔断器断开或SPD窗口显示红色,电工应检查/更换SPD。
Regularly inspect the operating status, especially after lightning. Once the fuse upstream breaks, or the SPD’s window indicates red, electrician should check/replace the SPD.
BT P DCM 12 RM
产品概述
BT P DCM 12 RM 是专为保护直流12V供电系统设计的电涌保护器,安装于LPZ0区域。本产品根据IEC 61643-11、GB/T 18802.11、YD/T 1235.1标准设计,适用于电信机房、微波通信等直流12V供电系统的保护。
Product Overview
BT P DCM 12 RM is specially designed for protecting 12V DC power supply systems from surge, installed at LPZ0. Designed according to IEC 61643-11, GB/T 18802.11, YD/T 1235.1 standards, suitable for DC 12V power supply systems such as telecommunication rooms and microwave communication systems.

技术参数 / Technical Specifications
20kA (0V-PE)
40kA (0V-PE)
≤ 400V (0V-PE)
≤ 100ns (0V-PE)
1.5mm²~25mm² solid / 35mm² flexible
DC:250V/0.1A,125V/0.2A,75V/0.5A
产品特点 / Product Features
直流保护 / DC protection
专为12V直流系统设计的电涌保护
Specially designed for 12V DC system surge protection
高性能 / High performance
体积小、残压低、快速响应
Compact size, low residual voltage, quick response
便捷更换 / Easy replacement
模块化设计,可插拔更换
Modular design, pluggable for easy replacement
状态指示 / Status indication
故障时绿色窗口变色
Green window changes color when fault occurs
应用范围 / Applications
BT P DCM 12 RM 适用于直流12V供电系统,例如用于电信机房、微波通信供电系统等。
典型安装位置 / Typical installation locations
- 配电箱
- UPS馈线总线
- LPZ0区域的直流供电系统
使用环境 / Application environment
- 工作温度:-40°C ~ +80°C
- 相对湿度:≤95% (25°C)
BT P DCM 12 RM is for DC 12V power supply systems, such as telecommunication rooms, microwave communication power supply systems and so on.
Typical installation locations
- Distribution boxes
- Feeder bus of UPS
- DC power supply systems at LPZ0
Application environment
- Temperature: -40°C ~ +80°C
- Relative humidity: ≤95% (25°C)
安装说明 / Installation Instructions
安装步骤
- 检查产品包装完整性,确保产品指示窗口没有显示红色
- 将本产品安装在标准的35mm DIN导轨上
- 连接导线,导线截面积必须大于4mm²。导线耐压值不小于AC50V,确保接线可靠
- 如需远程报警,应连接信号线至1和2或2和3端子(正常时1和2断开,2和3闭合;故障时状态相反)
- 安装完成后,接通电源并合上电路断路器。如果SPD窗口显示绿色,表示工作正常
后备保护要求
保险丝必须安装在SPD的上游,确保被保护系统具有双重保护。SPD系统中使用的保险丝值应满足:
- 保险丝的值不应大于SPD后备保险丝的最大耐受能力
- 在电源最大电流和闭合回路可用电流状态下,保险丝应能断开过载或短路电流
- 满足1.2级配置要求,保险丝应尽可能大以允许SPD的最大浪涌放电
Installation steps
- Check the product for integrity; ensure the product window doesn’t show red
- Mount the SPD on standard 35mm DIN rail
- Connect conductors, cross-sectional area must be >4mm². Withstand voltage ≥AC50V, ensure reliable wiring
- For remote alarm, connect to terminal 1-2 or 2-3 (normally 1-2 open, 2-3 close; reverses when fault)
- After installation, power on and close circuit breaker. Green window indicates normal operation
Backup protection requirements
Fuse must be installed upstream of SPD to ensure double protection. Fuse rating should:
- Not exceed SPD’s max. backup fuse withstand capacity
- Disconnect when overloaded or short-circuited under max. supply current
- Be as large as possible to allow SPD’s maximum surge discharge in 1.2 class configuration

特别警示 / WARNING:
1. 必须由具备电气专业技能的人员安装,符合国家标准和安全规范。
2. 建议在断电状态下进行安装。
1. The device must be installed by electrically skilled person, conforming to national standards and safety regulations.
2. It is recommended that installation should be done under power off condition.
维护说明 / Maintenance
应定期检查工作状态,特别是雷雨过后。一旦上游保险丝断开或SPD窗口显示红色,电工应检查/更换SPD。
Regularly inspect the operating status, especially after lightning. Once the upstream fuse breaks or SPD window shows red, electrician should check/replace the SPD.
BT PCM80 440 RM/4P
产品概述
BT PCM80 440 RM/4P 适用于安装在 LPZ0-1 或更高区域,保护低压设备免受电涌损坏。专为 TNC-S 系统(“4-0″电路)设计,适用于 SPD Class II (C级) 各种电源系统的雷电电流电涌保护。根据 IEC 61643-11、EN 61643-11、GB/T 18802.11 标准设计。
Product Overview
BT PCM80 440 RM/4P is for installation at LPZ0-1 or higher, protect low voltage devices from surge damages. Specially designed for TNC-S system (“4-0” circuit), applied to SPD Class II (Class C) for various power supply systems of lightning current surge protection. Designed according to IEC 61643-11; EN 61643-11; GB/T 18802-11.

技术参数 / Technical Specifications
1.5mm²~25mm² solid / 35mm² flexible
DC:250V/0.1A,125V/0.2A,75V/0.5A
产品特点 / Product Features
三相四线保护 / Three-phase protection
专为TNC-S系统(“4-0″电路)设计的三相四线保护
Three-phase protection specially designed for TNC-S system (“4-0” circuit)
高性能 / High performance
高放电能力(80kA),快速响应(≤25ns),可插拔设计
High discharge capacity (80kA), quick response (≤25ns), pluggable
双重保护 / Dual protection
双热脱扣装置,提供更可靠的保护
Double thermal disconnection devices, providing more reliable protection
状态指示 / Status indication
故障时窗口变红,同时提供远程报警控制
Window changes to red when fault occurs, with remote alarm control
应用范围 / Applications
BT PCM80 440 RM/4P 应用于三相 TNC-S 系统。主要用于配电室、配电柜和其他重要电源系统。
典型安装位置 / Typical installation locations
- 配电箱
- UPS馈线总线
- LPZ0-1区域的配电系统
使用环境 / Application environment
- 工作温度:-40°C ~ +80°C
- 相对湿度:≤95% (25°C)
BT PCM80 440 RM/4P is applied in three-phase TNC-S system. Mainly used in power supply system such as power distribution-room, distribution-cabinet and other important power supply system.
Typical installation locations
- Distribution box
- Feeder bus of UPS
- Power distribution systems at LPZ0-1
Application environment
- Temperature: -40°C ~ +80°C
- Relative humidity: ≤95% (25°C)
安装说明 / Installation Instructions
安装步骤
- 检查产品包装完整性,确保产品窗口未显示红色
- 将产品安装在35mm DIN导轨上
- 连接导线,导线截面积必须大于4mm²。导线耐压值不小于AC500V,确保接线可靠
- 如需远程报警,应连接信号线至1和3或2和3端子(正常时2和3断开,1和3闭合;故障时状态相反)
- 安装完成后,接通电源并合上电路断路器。如果SPD窗口显示绿色,表示工作正常
推荐配件 / Recommended accessories
母线排 BM-18-4 (货号: 850 004)
后备保护要求
熔断器必须安装在SPD的上游,确保被保护系统具有双重保护。SPD系统中使用的熔断器值应满足:
- 熔断器的值不应大于SPD后备熔断器的最大耐受能力
- 在电源最大电流和闭合回路可用电流状态下,熔断器应能断开过载或短路电流
- 综合考虑1和2点,熔断器应尽可能大以允许SPD的最大浪涌放电
Installation steps
- Check product integrity; ensure window doesn’t show red
- Mount on 35mm DIN rail
- Connect conductors (>4mm²), withstand voltage ≥AC500V
- For remote alarm, connect to terminal 1-3 or 2-3 (normally 2-3 open, 1-3 close; reverses when fault)
- After installation, power on and close circuit breaker. Green window indicates normal operation
Recommended accessories
Busbar BM-18-4 (Art. No.: 850 004)
Backup protection requirements
Fuse must be installed upstream of SPD to ensure double protection. Fuse rating should:
- Not exceed SPD’s max. backup fuse withstand capacity
- Disconnect when overloaded or short-circuited under max. supply current
- Be as large as possible to allow SPD’s maximum surge discharge

远程信号端子 / Remote terminals:
- 1. NC
- 2. NO
- 3. COM
特别警示 / WARNING:
1. 必须由具备电气专业技能的人员安装,符合国家标准和安全规范。
2. 建议在断电状态下进行安装。
1. The device must be installed by electrically skilled person, conforming to national standards and safety regulations.
2. It is recommended that installation should be done under power off condition.
维护说明 / Maintenance
应定期检查工作状态,特别是雷雨过后。一旦上游熔断器断开或SPD窗口显示红色,电工应检查/更换SPD。
Regularly inspect the operating status, especially after lightning. Once the fuse upstream breaks, or the SPD’s window indicates red, electrician should check/replace the SPD.